Sahar Najeeb Kharrufa and Firas Noori
Pertanika Journal of Science & Technology, Volume 30, Issue 1, January 2022
DOI: https://doi.org/10.47836/pjst.30.1.45
Keywords: Buildings in hot climates, cooling loads, evaporative air conditioning, traditional building designs
Published on: 10 January 2022
Most of the developed world currently lives above the tropic of Cancer in cold climate regions. It follows that most of the top architectural firms are from the same countries, and most of their work is based on that experience. Experience that does not travel well to hotter countries. This paper is mainly concerned with the climates of the Middle East region, which are hot in summer and have mild or cold winters, and where the humidity ranges from dry to humid. It is a review of the factors, designs, and solutions that designers sometimes ignore, undervalue, or on the other hand, put too much weight on when working in such climates. An overview of thermal solutions is conducted, and a critique and suitability of each one for hotter climates are offered. Some of the solutions, which are thought to be helpful, have little benefit, especially traditional ones, which are not up to present-day standards and lifestyles. Others, such as courtyards, do more harm than good. A couple of case studies to evaluate houses with and without thermal measures showed improvements of 23-48%. The paper will evaluate architectural, cooling, and building design solutions according to suitability in dry and medium humidity, warm and hot countries.
Akram, O. K., Ismail, S., Utaberta, N., Yunos, M. Y. M., Ismail, N. A., & Ariffin, N. F. M. (2015). The important values of architectural Baghdadi heritage. Advances in Environmental Biology, 9(24), 46-53.
Alalouch, C., Al-Saadi, S., AlWaer, H., & Al-Khaled, K. (2019). Energy saving potential for residential buildings in hot climates: The case of Oman. Sustainable Cities and Society, 46, Article 101442. https://doi.org/10.1016/J.SCS.2019.101442
Al-Homoud, M. S. (2016). The effectiveness of thermal insulation in different types of buildings in hot climates. Journal of Thermal Envelope and Building Science, 27(3), 235-247. https://doi.org/10.1177/1097196304038368
Al-Taie, E., Al-Ansari, N., Knutsson, S., Al-Taie, E., Al-Ansari, N., & Knutsson, S. (2014). The need to develop a building code for Iraq. Engineering, 6(10), 610-632. https://doi.org/10.4236/ENG.2014.610062
Amazon. (2017). Ceiling fan price. Retrieved April 1, 2017, from https://goo.gl/GYgk1F
Arasteh, D., Apte, J., & Huang, Y. (2003). Future advanced windows for zero-energy homes. ASHRAE Transactions, 109(2), 871-882.
Ariosto, T., Memari, A. M., & Solnosky, R. L. (2019). Development of designer aids for energy efficient residential window retrofit solutions. Sustainable Energy Technologies and Assessments, 33, 1-13. https://doi.org/10.1016/J.SETA.2019.02.007
ASHRAE. (2009). 2009 ASHRAE handbook: Fundamentals. American Society of Heating, Refrigeration and Air-Conditioning Engineers.
Bagasi, A. A., & Calautit, J. K. (2020). Experimental field study of the integration of passive and evaporative cooling techniques with Mashrabiya in hot climates. Energy and Buildings, 225, Article 110325. https://doi.org/10.1016/J.ENBUILD.2020.110325
Bansal, N. K., & Mathur, J. (2006). Energy efficient windows. Anamaya Publishers.
Boake, T. M., Bes, B., & Arch, M. (2014). Hot climate double façades: Avoiding solar gain. Facade Tectonics, 14, 2-24.
Buesing, J. W. (1981). Energy conserving window treatments: Insulated shades and draperies. Publication-Cooperative Extension Programs.
Butera, F., Adhikari, R., & Aste, N. (2014). Sustainable building design for tropical climates: Principles and applications for Eastern Africa. UN-Habitat.
Central Statistics Organization. (2015). Environmental indicators, Iraqi environmental statistics, (Table 3.1) daily average temperature and relative humidity for Baghdad. Iraqi Ministry of Planning.
Cuce, P. M., & Riffat, S. (2016). A state of the art review of evaporative cooling systems for building applications. Renewable and Sustainable Energy Reviews, 54, 1240-1249. https://doi.org/10.1016/J.RSER.2015.10.066
Del Barrio, E. P. (1998). Analysis of the green roofs cooling potential in buildings. Energy and Buildings, 27(2), 179-193. http://dx.doi.org/10.1016/S0378-7788(97)00029
Del Barrio, E. P. (1998). Analysis of the green roofs cooling potential in buildings. Energy and Buildings, 27(2), 179-193. https://doi.org/10.1016/S0378-7788(97)00029-7
Derradji, M., & Aiche, M. (2014). Modeling the soil surface temperature for natural cooling of buildings in hot climates. Procedia Computer Science, 32, 615-621. https://doi.org/10.1016/J.PROCS.2014.05.468
DEWA. (2015). Set your AC to 24°C. Dubai Electricity and Water Authority. Retrieved February 13, 2018, from https://www.dewa.gov.ae/en/customer/sustainability/spread-the-message/24-degrees-campaign
DEWA. (2018). Abu Dhabi power reduction. Dubai Electricity and Water Authority. Retrieved February 13, 2018, from http://www.powerwise.gov.ae/en/section/how-can-i-save-electricity/residential/air-conditioning
Dubai Municipality. (2021). Green building in Dubai. Retrieved October 14, 2021, from https://www.dm.gov.ae/municipality-business/al-safat-dubai-green-building-system/green-building-in-dubai/
Dylewski, R., & Adamczyk, J. (2011). Economic and environmental benefits of thermal insulation of building external walls. Building and Environment, 46(12), 2615-2623. https://doi.org/10.1016/j.buildenv.2011.06.023
Fasi, M. A., & Budaiwi, I. M. (2015). Energy performance of windows in office buildings considering daylight integration and visual comfort in hot climates. Energy and Buildings, 108, 307-316. https://doi.org/10.1016/J.ENBUILD.2015.09.024
Garde, F., David, M., Lenoir, A., & Ottenwelter, E. (2011). Towards net zero energy buildings in hot climates: Part 1, new tools and methods. ASHRAE Transactions, 117(1), 450-457.
Hashemi, N., Fayaz, R., & Sarshar, M. (2010). Thermal behavior of a ventilated double skin facade in hot arid climate. Energy and Buildings, 42(10), 1823-1832. https://doi.org/10.1016/j.enbuild.2010.05.019
Hawkes, D., & Forster, W. (2002). Energy efficient buildings: Architecture, engineering, and environment. WW Norton & Company.
Hedayat, Z., Belmans, B., Ayatollahi, M. H., Wouters, I., & Descamps, F. (2015). Performance assessment of ancient wind catchers - An experimental and analytical study. Energy Procedia, 78, 2578-2583. https://doi.org/10.1016/J.EGYPRO.2015.11.292
Kanaan, A., Sevostianova, E., Donaldson, B., & Sevostianov, I. (2021). Effect of different landscapes on heat load to buildings. Land, 10(7), Article 733. https://doi.org/10.3390/LAND10070733
Kaynakli, O. (2012). A review of the economical and optimum thermal insulation thickness for building applications. Renewable and Sustainable Energy Reviews, 16(1), 415-425. https://doi.org/10.1016/j.rser.2011.08.006
Kharrufa, S. N. (2008). Evaluation of basement’s thermal performance in Iraq for summer use. Journal of Asian Architecture and Building Engineering, 7(2), 411-417. https://doi.org/10.3130/jaabe.7.411
Kharrufa, S. N., & Adil, Y. (2008). Roof pond cooling of buildings in hot arid climates. Building and Environment, 43(1), 82-89. https://doi.org/10.1016/j.buildenv.2006.11.034
Kharrufa, S. N., & Adil, Y. (2012a). Reducing the cooling load by evaporative cooling of the roof. In Energy and Buildings: Efficiency, Air Quality, and Conservation (pp. 235-255). Nova Publishers. https://doi.org/10.1016/j.enbuild.2012.09.006
Kharrufa, S. N., & Adil, Y. (2012b). Upgrading the building envelope to reduce cooling loads. Energy and Buildings, 55, 389-396. https://doi.org/10.1016/j.enbuild.2012.09.006
Lechner, N. (2014). Heating, cooling, lighting: Sustainable design methods for architects. John Wiley & Sons.
Lee, J. W., Jung, H. J., Park, J. Y., Lee, J. B., & Yoon, Y. (2013). Optimization of building window system in Asian regions by analyzing solar heat gain and daylighting elements. Renewable Energy, 50, 522-531.https://doi.org/10.1016/j.renene.2012.07.029
McQuiston, F. C., Parker, J. D., & Spitler, J. D. (2004). Heating, ventilating, and air conditioning: Analysis and design. John Wiley & Sons.
Mehere, S. V, Mudafale, K. P., & Prayagi, S. V. (2014). Review of direct evaporative cooling system with its applications. International Journal of Engineering Research and General Science, 2(6), 995-999.
Mushtaha, E., & Helmy, O. (2016). Impact of building forms on thermal performance and thermal comfort conditions in religious buildings in hot climates: A case study in Sharjah city. International Journal of Sustainable Energy, 36(10), 926-944. https://doi.org/10.1080/14786451.2015.1127234
NCM. (2021). Climate yearly report 2003-2017. National Center of Meteorology. Retrieved June 2, 2021, from https://www.ncm.ae/services/climate-reports-yearly?lang=en
Nicol, F., Humphreys, M., & Roaf, S. (2012). Adaptive thermal comfort: Principles and practice. Routledge.
Pal, R. K., Goyal, P., & Sehgal, S. (2020). Thermal performance of buildings with light colored exterior materials. Materials Today: Proceedings, 28, 1307-1313. https://doi.org/10.1016/J.MATPR.2020.04.508
Rackes, A., Melo, A. P., & Lamberts, R. (2016). Naturally comfortable and sustainable: Informed design guidance and performance labeling for passive commercial buildings in hot climates. Applied Energy, 174, 256-274. https://doi.org/10.1016/J.APENERGY.2016.04.081
Sajjad, U., Abbas, N., Hamid, K., Abbas, S., Hussain, I., Ammar, S. M., Sultan, M., Ali, H. M., Hussain, M., Ur-Rehman, T., & Wang, C. C. (2021). A review of recent advances in indirect evaporative cooling technology. International Communications in Heat and Mass Transfer, 122, Article 105140. https://doi.org/10.1016/J.ICHEATMASSTRANSFER.2021.105140
Saleem, J. (1986). Improving performance of evaporative coolers. In Proceedings of Fifth Annual Scientific Symposium of Iraqi Research Council. Baghdad, Iraq.
Sharifi, A., & Yamagata, Y. (2015). Roof ponds as passive heating and cooling systems: A systematic review. Applied Energy, 160, 336-357. https://doi.org/10.1016/j.apenergy.2015.09.061
Shi, Z., & Zhang, X. (2011). Analyzing the effect of the longwave emissivity and solar reflectance of building envelopes on energy-saving in buildings in various climates. Solar Energy, 85(1), 28-37. https://doi.org/10.1016/J.SOLENER.2010.11.009
Vijayaraghavan, K. (2016). Green roofs: A critical review on the role of components, benefits, limitations and trends. Renewable and Sustainable Energy Reviews, 57, 740-752. https://doi.org/10.1016/J.RSER.2015.12.119
Williams, G. P., & Gold, L. W. (1976). CBD-180 ground temperatures. National Research Council Canada.
Yang, Y., Cui, G., & Lan, C. Q. (2019). Developments in evaporative cooling and enhanced evaporative cooling - A review. Renewable and Sustainable Energy Reviews, 113, Article 109230. https://doi.org/10.1016/J.RSER.2019.06.037
Zarandi, M. M. (2009). Analysis on Iranian wind catcher and its effect on natural ventilation as a solution towards sustainable architecture (Case Study: Yazd). World Academy of Science, Engineering and Technology, 54, 574-579.